Change of IDE-RAID Maintenance Method
- Document ID: 98080124
- Posted Date: 2002-12-05
- Last Updated: 2002-12-05
- Distribution: View Public Website
- Issue
When the BIOS is updated to 2.5.11130008T (System BIOS 1.15TE) after configuring RAID1 with old IDE-RAID extended BIOS 2.5. 07172126A (previous to System BIOS 1.07PD), the following message may appear and halt rebuild during the execution of extended-BIOS:
"Warning!! Stripe size is smaller than size of mirror. Continue (y/n)"
Cause:
The RAID configuration information has changed.- Resolution
- Preventive measure:
Reconfigure Array by using current extended BIOS 2.5.11130008T (System BIOS 1.15TE) - Corrective measure for error symptom:
Rebuild after reconfiguring Array.
- Preventive measure:
- Export Control and EULA
- Use of any software made available for download from this system constitutes your acceptance of the Export Control Terms and the terms in the Dynabook end-user license agreement both of which you can view before downloading any such software.