Change of IDE-RAID Maintenance Method



Document ID: 98080124

 

Posted Date: 2002-12-05

 

Last Updated: 2002-12-05

 

Distribution: View Public Website

 

Issue

When the BIOS is updated to 2.5.11130008T (System BIOS 1.15TE) after configuring RAID1 with old IDE-RAID extended BIOS 2.5. 07172126A (previous to System BIOS 1.07PD), the following message may appear and halt rebuild during the execution of extended-BIOS:
"Warning!! Stripe size is smaller than size of mirror. Continue (y/n)"

Cause:
The RAID configuration information has changed.

Resolution
  1. Preventive measure:
    Reconfigure Array by using current extended BIOS 2.5.11130008T (System BIOS 1.15TE)
  2. Corrective measure for error symptom:
    Rebuild after reconfiguring Array.