Applicable Models
Tecra 8200

 

Issue
Event Viewer reports the Puma IRComm driver and the Puma IRLpt driver failed to start. These errors will occur if the IrDA Port is set to disabled under Toshiba HW setup.
Resolution

This issue can be resolved by assigning resources to the IrDA Port using the following procedure:

  1. Click on the Windows NT "Start Menu" and select "Settings" and then select "Control Panel".
  2. In Control Panel select "Toshiba HW Setup" and then select the "Serial" tab.
  3. Under IrDA Port change the setting from "Not Used" to "120H/2F8H/3" and set the DMA Channel to "1".